When firefighters arrive at a fire scene, one of their first tasks is to choose the best water source to combat the specific type of fire. The amount of water needed to extinguish a burning car is obviously significantly lower than that of an apartment building. Firefighters can estimate the amount of water needed to put out a certain fire using specific calculations. The amount of water that a fire hydrant can supply is typically indicated by its color code. When determining which hydrant to use, this facilitates rapid decision-making.
The available gallons per minute (GPM) of water for firefighting purposes is the standard measurement. Water for most cities and suburbs comes from a distant lake or reservoir. Every house and building in a certain area gets its water supply via a network of pipes, some of which run below ground and others above. It is the responsibility of the water district that supplies the water to maintain all water systems.
Water for drinking, bathing, washing clothes, and watering the lawn account for the vast majority of its use. It is the responsibility of water districts to make sure that firefighters have access to water in the event of a fire. They accomplish this by utilizing the well-known fire hydrant. Available supply might range from 500 GPM or less to more than 2500 GPM, thanks to the many diverse delivery systems in the US.
The NFPA has issued a recommendation for standardized color-coding among fire departments and water districts in an attempt to facilitate firefighters’ ability to determine the supply that a given hydrant will provide. Fire hydrants that draw water from public systems are required by National Fire Protection Association Standard 291 to be painted chrome yellow and to display the available GPM on the top and cap of the hydrant. The appropriate colors for this range of GPM are red for 500 GPM and orange for 500 to 999 GPM, green for 1000 to 1499 GPM, and blue for 1500 GPM and above.
It is expected that fire hydrants be painted a different color to indicate that they are not connected to a public water system but are instead drawing water from a private system, such as a shared well in a community. NFPA suggests using red.
According to OSHA, a hydrant should be painted violet if the source is non-potable. However, it is unclear what color to paint a hydrant that is non-potable and comes from a private source. Also, a hydrant that isn’t working should be painted black. It is usual practice to cover the hydrant with a black bag if its inoperable period is likely to be brief.
There are two aspects to water supply besides GPM. Psi is the unit of measurement for pressure, the other of which is volume. It is presumed that all hydrants supply a minimum of 20 psi. Not having the rated pressure stenciled on the hydrant’s top and caps is something the NFPA suggests in such a case. Hydrants with exceptionally high pressures are also advised to use this. Without proper safety measures, excessive pressure can harm the fire apparatus.
Most water and fire departments make an effort to adhere to these guidelines set by the NFPA. These are merely recommendations, though, and by no means an exhaustive list. Therefore, not all regions will implement these suggestions. Nearly half of the fire departments surveyed by Firehouse.com in 2005 used this color-coding scheme, while nearly half did not. Hydrants were not available to 8% of the people who took the survey. When fire hydrants are not available, tenders, which are trucks that carry water, will fill up with water from nearby bodies of water like rivers and lakes and then transport it to the fire.
Color coding is utilized in many contexts than only the NFPA suggestion. Each town makes its own unique one based on its own unique circumstances. One example is how the Moraga-Orinda (CA) Fire District has implemented NFPA-recommended color coding for the hydrant caps. After then, each PSI is assigned a color code for the caps. sometimes shown are hydrants that may only be filled from one direction, sometimes known as dead ends. A unique color scheme for hydrant bodies and an arrow system to denote hydrants with higher pressures are used by them. Additionally, they feature Roman number markings that point to the location of the hydrant’s shutoff valves.
You may rest confident that every hue has a purpose when you see a hydrant painted a specific color while driving around your area. Anyone who has a fire hydrant on their property probably tries to cover it up with flowers, butterflies, and other creative embellishments. The local water district or fire department may show up at your home to advise you that your amateur art is not welcomed if you do that.
Hydrant Facts
- The majority of water distribution systems, such as those serving big cities and towns, have a grid-based design. All of the distribution pipes in such a system are linked to one another. Water can be provided from a different direction in the event that one pipe becomes damaged or clogged, ensuring that the end user continues to have uninterrupted water supply. A dead-end hydrant is one that receives water solely from one source.
- A fire can’t stay lit without these four components. The chemical process involving heat, fuel, and oxygen. To extinguish the fire, you need just remove one of those four items. The majority of methods employ the use of water.
A double-edged sword: water and fire. The first one is obvious: it lowers the temperature of the burning fuel below the critical point, or fire point, at which it will continue to burn. Two, it’s not immediately apparent. The water boils into steam when it is enclosed and exposed to the available heat. Smothering the fire, the steam essentially replaces the oxygen that was previously there. Several variables, such as the water’s temperature, the surrounding temperature, and air pressure, determine the quantity of steam produced by the water. The ratio of 1700 to 1 is used by firemen for practical purposes. The amount of steam produced is equal to 1,700 times that of water. - When selecting how to put out a fire, one of the most crucial considerations is the amount of water that will be required. There is insufficient water to extinguish the fire. If you use too much, the remaining occupants you’re attempting to keep dry will suffer water damage. Envision a situation where a single room on the upper floor of your house catches fire, while the entire lower floor is submerged by water caused by an enthusiastic amateur. On their next levy, you might want to think again before voting yes.
- The formula for calculating the appropriate water quantity to extinguish a specific fire depends on a number of factors, including, but not limited to, the nature of the burning material, the area engulfed in flames, and the fire hose nozzle selected, among many others. The standard procedure, like with most things related to firefighting, provides a ballpark figure for the required GPM. The volume of the stuff being burned divided by 3. You, too, may now judge for yourself whether the water from the hydrant outside your home is sufficient to extinguish the fire in your mattress!
As you drive through your neighborhood and spot these vibrant fixtures, each color serves a purpose, guiding firefighters and residents alike. From the NFPA-recommended color codes denoting water pressure to distinct practices adopted by local districts, every shade signifies critical information for efficient firefighting. These hydrants, though often overlooked, play a pivotal role in safeguarding communities.